{"product_id":"decoderwerk-30103-1-channel-turnout-decoder-suitable-for-all-solenoid-operated-drives-dcc-motorola","title":"Decoderwerk 30103 1-channel turnout decoder suitable for all solenoid-operated drives (DCC + Motorola)","description":"\u003ch2 class=\"product-addition-headline\"\u003eDescription\u003c\/h2\u003e\n\u003cdiv class=\"product-addition-content\" itemprop=\"description\"\u003e\n\u003cul\u003e\n\u003cli\u003eThe decoder has 1 output.\u003c\/li\u003e\n\u003cli\u003eDCC \u0026amp; Märklin Motorola Operation can be done with DCC or Märklin\u003cstrong\u003e\u003cspan\u003e® \u003c\/span\u003e\u003c\/strong\u003eMotorola.\u003c\/li\u003e\n\u003cli\u003eThe decoder is suitable for single-set switches with double spool drive or two decoupling tracks.\u003c\/li\u003e\n\u003cli\u003e100% quality check of all decoders\u003cbr\u003eDevelopment and production in Germany\u003cbr\u003eWe only use components of well-known brand manufacturers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eVoltage\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuild up\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e9-24V track voltage\u003c\/li\u003e\n\u003c\/ul\u003e\nThe decoder is supplied directly by the track voltage. No separate power supply can be connected.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePerformance\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e9-24V DC voltage\u003c\/li\u003e\n\u003cli\u003e2A current\u003c\/li\u003e\n\u003c\/ul\u003e\nThe output can be loaded with 2A and delivers 9-24V DC voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNeed\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eQuiet current below 5mA\u003c\/li\u003e\n\u003c\/ul\u003e\nThe decoder itself requires under 5mA in the idle mode. The power demand of the output depends on the connected article.\u003c\/li\u003e\n\u003cli\u003eThe decoders are protected against short circuit with a self-resetting fuse.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong conclusion \u003c\/strong\u003eThe decoders have a charging control, so that the control panel does not mistakenly diagnose a short circuit when starting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCoupling\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eArtificial intelligence\u003c\/strong\u003e, at least a little. The decoder has an automatic learning mode for addressing. You just have to press a button and call up the desired address at your headquarters. Done.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote control \u003c\/strong\u003eThe decoder can be configured directly at its place of use from a DCC control panel by means of programming-on-main. All CV's can be updated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspection \u003c\/strong\u003eThe decoder can be configured on a DCC programming track. All CV's can be read and written via direct mode.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eConfiguration\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard \u003c\/strong\u003eBy default, each output generates a switching pulse of 400 ms.\u003c\/li\u003e\n\u003cli\u003eSmall steps You can adjust the switching pulse individually. Switching pulses from 10 ms to 2,550 ms are possible. And that in small steps of 10ms.\u003c\/li\u003e\n\u003cli\u003eIf the switching time is increased, the output remains activated as long as the button on the control panel is pressed. Thus, for example, decoupling tracks can be precisely controlled.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eForever \u003c\/strong\u003eThe output can be configured as continuous operation. The output is switched until it is deactivated by selecting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections \u003c\/strong\u003ePhoenix Contact brand terminals for cables up to 1mm2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions \u003c\/strong\u003e25x50mm, 20mm high\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFastening \u003c\/strong\u003e2 mounting holes of size M3. The inner diameter is 3.5mm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e \u003cp\u003eDecoderwerk user guides for most products (with english text) can be found \u003ca href=\"https:\/\/decoderwerk.com\/i\/downloads\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e","brand":"Decoderwerk","offers":[{"title":"Default Title","offer_id":52692623687960,"sku":"IC-DWERK-30103","price":24.95,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0753\/7023\/4136\/files\/decoderwerk-30103-1-channel-turnout-decoder-suitable-for-all-solenoid-operated-drives-dcc-motorola-stationary-decoders-340.jpg?v=1789621101","url":"https:\/\/ictrainsandhobbies.com\/products\/decoderwerk-30103-1-channel-turnout-decoder-suitable-for-all-solenoid-operated-drives-dcc-motorola","provider":"InterCity Trains and Hobbies","version":"1.0","type":"link"}